The standards and codes of practice our work rests on, and our own guides to applying them. Search the lot, or go to a section.
Nothing matches that search. Try a standard number or a roof type, or ask us.
Standards and codes of practice
What each document says about leak detection, testing and inspection, cited by edition and clause.
- BSI
BS 8102:2022 — Permanent Leak Detection as a Design Requirement
Principal BS governing protection of below-ground structures. Section 6.5 Note 2 is the basis for permanent leak detection on buried decks with warm roof build-ups or loose-laid waterproofing.
- BSI
BS 6229:2025 — Flat Roof Inspections and Testing
Current British Standard for flat and curved roofs with continuously supported flexible waterproof coverings. Covers design information, integrity testing, inspection, care and maintenance. Clause 8.2 recommends inspection at least twice yearly; Note 2 recognises electronic devices for leak and heat-loss detection.
- FPA / RISCAuthority / CIREG
Joint Code of Practice — Escape of Water Prevention on Construction Sites
JCoP (2024) by RISCAuthority and CIREG. Mandatory Water Systems Management Plans, automated shut-off valves and leak sensors on all water risers on insured construction sites.
- CIRIA
CIRIA C817 (2024) — Blue Roofs: A Guide to Implementation
Definitive UK guidance on blue roof design and implementation. Vector technical director Ben Hickman was a Key Technical Author of this publication.
- Liquid Roofing and Waterproofing Association
LRWA GN18:2025 — Electronic Integrity Testing of Waterproofing Membranes
LRWA Guidance Note 18 (2025). Non-destructive electronic integrity testing of waterproofing membranes — low-voltage and high-voltage methodology, operator competence and reporting.
- BSI
BS EN 16893:2018 — Storage of Heritage Collections
Where assessment identifies a high risk of external water ingress, BS EN 16893 requires leak detection with an alarm — plus monitoring of drainage, pipework and other water sources, and continuous environmental monitoring. What clauses 5.7.1–5.7.3 require.
Specifying and designing monitoring
Whether to specify permanent leak detection, how to write it into the build-up, and how the systems compare.
- Vector article
What Are the Best Smart Roof Leak Detection Systems? A UK Comparison (2026)
An independent-standard comparison of smart roof leak detection systems available to UK specifiers — Sensor Innovation, Tector, VILPE Sense, Sika, Detec PermaScan, ProGeo smartex and others — what each detects, where it sits, what the evidence shows, and which suits which roof.
- Vector article
NBS Specification for Roof Leak Detection: Uniclass Codes and Model Clause Text
Where roof leak detection sits in an NBS specification, the Uniclass 2015 codes to use (Ss_75_50_50_96 and the Pr_75_50_48 liquid-sensing devices), and model clause text in the NBS system-clause shape for both permanent leak detection and independent quality assurance (integrity testing) of the waterproofing, with the rule for when each applies.
- Vector article
Should You Specify Leak Detection in This Roof?
A decision guide for UK architects: which flat roofs need permanent leak detection and which do not, what independent quality assurance of the waterproofing means, what NHBC Standards 2026 and BS 6229:2025 actually ask for, when in the RIBA stages to decide, what detection will and will not do, and how it affects the guarantee. Technology-neutral.
- Vector article
How Many Leak Sensors Does a Roof Actually Need?
There is no sensors-per-square-metre answer, and anyone giving you one has not seen your roof. The rule that does govern sensor layout comes from BS 8102:2022, and it is economic as much as technical.
- Vector article
Smart Roof Monitoring: What It Is, How It Works, and What It Cannot Do
Smart roof monitoring, permanent leak detection and integrated leak detection describe the same thing. What the technique actually detects, the five system types, how zone size is governed, and where the standards sit.
- Vector article
Permanent Monitoring vs Electronic Integrity Testing: Two Different Things
Both get written into specifications as leak detection, and they answer completely different questions. What LRWA GN18:2025 covers, what it does not, and why a well-specified roof has both.
- Vector article
How to Specify a Smart, Integrated Leak Detection System in a Roof Build-Up
The clause usually reads as one line. Here is what a specification for permanent leak detection in a roof build-up actually has to settle — position, power, zoning, service life, commissioning and warranty — with model performance wording.
- Vector article
Leak Detection for Data Centre Roofs: What to Specify, and When
Integrated leak detection is increasingly specified on data centre roofs — but rarely detailed. An independent UK consultant on the options, the pitfalls, and when to decide.
- Vector article
Permanent Roof Leak Monitoring: Sensor Technology Guide
How permanent roof leak sensors work, where they sit in the build-up, what the standards say, and what a monitoring system costs against the cost of an undetected leak. A guide for architects, contractors and building owners.
Commissioning, QA and reducing risk
Checking the roof before it is covered, and designing a roof that can be repaired.
- Vector article
High-Risk Flat Roof? How to Reduce the Risk
What makes a flat roof high-risk for leaks, a simple risk score an architect can use, and the seven design-stage levers that reduce it: deck, falls, bond, build-up, independent quality assurance, permanent leak detection where the waterproofing is covered, and ownership after handover. Clause references to BS 6229:2025, NHBC Standards 2026, CIRIA C817 and the PCA buried roofs guidance.
- Vector article
What Is the Most Robust Flat Roof Waterproofing System?
There is no most robust membrane. A flat roof is robust when a leak can be found and repaired locally, and there are two ways to design for that: a monolithic membrane bonded to a concrete deck cast to falls, or a separated system on tapered insulation with smart leak detection built in. What each route needs, where the UK standards sit, and what to specify on green, blue, podium and buried roofs.
- Vector article
Waterproofing QA — The Step Everyone Skips
Waterproofing QA is the step everyone skips. What commissioning testing involves, what happens when it's missed, and why insurers expect documented evidence.
- Vector article
Defect Liability Period Roof Risk
How to manage roof leak risk during the defect liability period. Protect your investment with sensor monitoring and independent leak investigation while the contractor is still on the hook.
Finding leaks
Methods for locating a breach, and what works under green roofs, paving and ballast.
- Vector article
Can You Find a Leak Without Removing the Green Roof?
Yes. A buried leak location survey reads the waterproofing membrane through the planting, substrate and drainage layer and plots the breach on the roof plan, so the only opening-up is about a square metre at a marked position. How it works, what it needs, and when it cannot be done.
- Vector article
Green Roof Leak Survey: What a Building Surveyor Should Specify
A building surveyor instructing a leak investigation on a green roof, podium deck or other buried membrane: the method to specify, the information to provide, the deliverables to require, and the step that is most often left out. With suggested instruction wording.
- Vector article
Green Roof Leaking After Heavy Rain: What to Do
A green roof that leaks only in heavy or prolonged rain has a defect that normal weather does not reach. What a facilities manager, asset manager or surveyor should do in the first week, what not to let a roofer do, and how the breach is found through the build-up without stripping the roof.
- Vector article
Why Does a Green Roof Only Leak in Heavy Rain?
A green roof that leaks only in heavy or prolonged rain has a defect that ordinary weather does not reach. Water accumulates in the build-up to abnormal depths, exposes the breach, then travels sideways before it shows inside, often ten to fifty metres away. What that means for finding and fixing it.
- Vector article
How Can I Find a Leak in a Green Roof?
You find a green roof leak from the top down, not by chasing the ceiling stain. Why the point of ingress is not where the membrane failed, how buried leak location finds the defect without stripping the roof, and why sensors built into the roof solve it for good.
- Vector article
Electronic Leak Detection — The Complete UK Guide
High-voltage vs low-voltage electronic leak detection, membrane compatibility, BS 6229:2025, reporting and specification — independent UK guidance from Vector.
- Vector article
The Cheapest Roof Inspector Will Cost You More
Twice-yearly roof inspections are commonly a guarantee condition — not a box-ticking exercise. Using unqualified inspectors can invalidate guarantees and now carries legal risk under the Building Safety Act 2022.
- Vector article
Flat Roof Leak Detection: 9 Methods Compared
All nine professional flat roof leak detection methods compared — electronic integrity testing, moisture mapping, tracer gas, thermography, buried leak location — and how to choose.
- Vector article
You’ve Got a Roof Leak. Here’s How We’d Approach It.
Not every roof leak needs sophisticated equipment. Some need a torch and twenty years of knowing where to look. How a competent investigation actually works — step by step.
- Vector article
Green Roof Leak Detection: Why Standard Methods Fail
Why visual inspection, dye and flood tests, thermal imaging and conventional electronic leak detection fail once a membrane is buried under a green roof; what finds the breach through the build-up; and how to make it the last investigation the roof ever needs.
- Vector article
What Is Buried Leak Detection?
Buried leak detection explained: how electronic methods locate concealed leaks in complex roof and waterproofing systems without destructive investigation.
Mass timber and CLT
Moisture thresholds, monitoring methods, the moisture control plan and the case law.
- BSI
CLT and Mass Timber — Moisture Monitoring in Modern Construction
BS 5250:2021, BS EN ISO 6781-1:2023, PAS 2035:2023 and BS 40101:2022. Standards and guidance relevant to moisture management, building-performance evaluation and diagnostic investigation in mass-timber construction.
- Vector guidance
Moisture Management in Mass Timber and CLT — the Structural Engineer’s Guide
The pillar guide: safe moisture-content thresholds, the Construction Stage Moisture Control Plan, monitoring methods, decay risk and the standards framework for mass timber buildings.
- Vector guidance
CLT Moisture Content Thresholds — What Is Safe, and When to Act
The numbers that matter: equilibrium moisture content, the 16% caution line, the 20% decay threshold, and what sustained readings above each level mean for a load-bearing panel.
- Vector guidance
Monitoring Moisture in Mass Timber — Methods Compared
Resistance pins, capacitance sensors, RH probes and embedded wireless systems compared — accuracy, lifespan, retrofit options and where each belongs in a monitoring strategy.
- Vector guidance
The Construction Stage Moisture Control Plan
Who owns moisture risk during a mass timber build, what a CSMCP contains, and how wetting events, drying verification and sign-off gates are documented before enclosure.
- Case law review
CLT Moisture Failures in the Courts — What the Case Law Teaches
Reported disputes and claims arising from moisture damage in CLT buildings — what failed, who carried the liability, and the monitoring evidence that decided the outcomes.
- Vector article
CLT Moisture Monitoring for Timber Buildings
Why CLT structures need permanent moisture monitoring, where sensors should be placed, what the standards and the courts now expect, and what continuous data tells building owners, insurers and warranty providers.